Image from Google Jackets
Image from OpenLibrary

Calculating cooling time of brewed coffee using differential equation Danica A. Quirido... [et.al].

Contributor(s): Material type: TextTextLanguage: English Publication details: 2016Description: 52 leaves : illustrations ; 28 cmSubject(s): LOC classification:
  • QA 11 .C127 2016
Dissertation note: Thesis (Bachelor of Science in Mathematics) -- University of Rizal System-Morong. Summary: EXECUTIVE SUMMARY: The study on the calculating cooling time of brewed coffee using differential equation. This was conducted at the University of Rizal System Morong during the first semester of school year 2015-2016. The experiment was conducted in the different coffee shops in Morong, Rizal namely; Infini Tea, Aljen's Coffee Break Lounge, Scholar's Café, Bean in Love. The researchers used the Newton's formula for Cooling and Heating to test if the computed temperature would be equal to the actual data gathered. After using the said formula the researchers concluded that the time rate of change of the temperature of the coffee is proportional to the difference between the coffee and its surrounding medium. The lower the surroundings temperature the shorter time the coffee decreases its temperature and the higher surrounding temperature the longer time the coffee decreases its temperature. The researchers recommend that further studies may be conducted using Cooling and Heating in Differential Equation in other situations.
Tags from this library: No tags from this library for this title.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Copy number Status Date due Barcode
Theses and dissertations Theses and dissertations Morong College Library Reference QA 11 .C127 2016 (Browse shelf(Opens below)) 1 Not for loan URSMOR-CL-004400

Thesis (Bachelor of Science in Mathematics) -- University of Rizal System-Morong.

EXECUTIVE SUMMARY: The study on the calculating cooling time of brewed coffee using differential equation. This was conducted at the University of Rizal System Morong during the first semester of school year 2015-2016. The experiment was conducted in the different coffee shops in Morong, Rizal namely; Infini Tea, Aljen's Coffee Break Lounge, Scholar's Café, Bean in Love. The researchers used the Newton's formula for Cooling and Heating to test if the computed temperature would be equal to the actual data gathered. After using the said formula the researchers concluded that the time rate of change of the temperature of the coffee is proportional to the difference between the coffee and its surrounding medium. The lower the surroundings temperature the shorter time the coffee decreases its temperature and the higher surrounding temperature the longer time the coffee decreases its temperature. The researchers recommend that further studies may be conducted using Cooling and Heating in Differential Equation in other situations.