Chilled water air conditioning trainer unit John Julian F. Francisco...[et.al].

Contributor(s): Material type: TextTextLanguage: English 2016Description: 66 leaves : illustrations ; 28 cmSubject(s): LOC classification:
  • TP 492 .C538 2016
Dissertation note: Thesis (Bachelor of Science in Mechanical Engineering) -- University of Rizal System-Morong. Summary: EXECUTIVE SUMMARY: The thesis entitled "Chilled Water Air Conditioning Trainer Unit" was developed to serve as an trainer to be used by students and instructors. The developed device was composed of ¾ HP Air Conditioning Unit, Cooling tower, water pump, Air handling Unit and trainer board made from locally materials. The Cooling tower was made of stel angle bar and plain metal sheet. Developmental and Descriptive research were used by the researchers in this study to complete the output. The level of acceptability of the trainer unit in terms of functionality and durability was evaluated Extremely Accepted by students and experts, while in terms of safety the level of acceptability was rated Very Much Accepted by the students and the Experts. Based on the summary of the design results, the researchers concluded that the developed project obtained its function and objectives.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Copy number Status Date due Barcode
Theses and dissertations Theses and dissertations Morong College Library On Display Reference TP 492 .C538 2016 (Browse shelf(Opens below)) 1 Not for loan URSMOR-CL-004563

Thesis (Bachelor of Science in Mechanical Engineering) -- University of Rizal System-Morong.

EXECUTIVE SUMMARY: The thesis entitled "Chilled Water Air Conditioning Trainer Unit" was developed to serve as an trainer to be used by students and instructors. The developed device was composed of ¾ HP Air Conditioning Unit, Cooling tower, water pump, Air handling Unit and trainer board made from locally materials. The Cooling tower was made of stel angle bar and plain metal sheet. Developmental and Descriptive research were used by the researchers in this study to complete the output. The level of acceptability of the trainer unit in terms of functionality and durability was evaluated Extremely Accepted by students and experts, while in terms of safety the level of acceptability was rated Very Much Accepted by the students and the Experts. Based on the summary of the design results, the researchers concluded that the developed project obtained its function and objectives.