000 02996nam a22003137i 4500
003 URS
003 URS
005 20240416181557.0
008 170627b xxu||||| |||| 00| 0 eng d
040 _aURS
_beng
_erda
041 _aeng
050 0 0 _aTP 492
_b.M72 2015
245 _aModified refrigerant recovery unit
_cRey Mark B. Bautista... [et.al].
264 _c2015
300 _a95 leaves :
_billustrations ;
_c28 cm.
336 _atext
_btxt
_2rdacontent
337 _aunmediated
_bn
_2rdamedia
338 _avolume
_bnc
_2rdacarrier
502 _bThesis (Bachelor of Technology major in Electromechanical Technology) -- University of Rizal System-Morong.
520 _aEXECUTIVE SUMMARY: This study aimed to developed and construct a Modified Refrigerant recovery Unit specifically, it aimed to design and construct a recovery unit out of locally available materials and determined the acceptability of the project in terms of Usefulness, functionality, safety, maintenance and durability features and test the significant difference between the acceptability and performance of the existing recovery unit and modified refrigerant recovery unit. It was conducted at the University of Rizal System Morong Campus during S.Y. 2015-2016 It utilized developmental and descriptive methods of research to determine the acceptability of the modified refrigerant recovery unit. Also, an adapted and modified checklist was used and validated by 10 experts and 10 end-users from Electromechanical and Electrical Technology in the College of Industrial Technology. Try-out and revision were also done by the researchers during trial and the corresponding revision to correct this effects. After the construction of the Modified Refrigerant recovery unit its operation were tested and correction were made on the defective parts and components. Based on the summary of findings, the developed Modified refrigerant recovery unit found to be extremely accepted as compared to existing recovery unit as to usefulness, functionality, safety, maintenance and durability as evaluated by the experts and the end-users. The study concluded that, the developed modified refrigerant recovery unit has no significant difference on the existing recovery unit in terms of usefulness, functionality, safety, maintenance, durability, time of recovering refrigerant amount of refrigerant recovered. Based from the result of the findings and conclusion, the study recommended that, financial support should be given for implementation and lastly, parallel study should be made to understand and improve this study.
650 _aRefrigeration and refrigerating machinery.
700 1 _aBautista, Rey Mark B.
_eauthor
700 1 _aAbucot, John Michael S.
_eauthor
700 1 _aBeato, Jerome A.
_eauthor
700 1 _aCod, Jeffrey L.
_eauthor
700 1 _aSto. Domingo, Marco R.
_eauthor
856 _3Online Request for Student Unpublished Works
_uhttps://forms.gle/7LqvGGkaDrUQqz429
942 _2lcc
_cT
999 _c74660
_d74659